Checking Bolt Tension A Month Later

Just enter the temperature, get a good signal,
and record the new tension.

 
 

SureBolt automatically sets the pointer to the same position and shows you last month's temperature when the bolt had zero tension.

Notice how today's 23.9 deg C temperature is 1.8 deg C higher than last month. Then notice the left pointing red arrow, showing how temperature caused the echo to delay 0.012 usec.

Now for the tricky part. You need to get the transducer positioned very similar to last month's reading. Just keep positioning the transducer until the echo looks very similar. Isn't it nice that SureBolt lets you see last month's echo?

 



Repeatable signal
.
  Enter the new temperature in the "Latest Temp" box.

<<Back 

 

See below for each of the NEW screens in this example (only those screens that require you to do something different than manufacturer #1). You can jump to any screen you want, but we recommend going back to manufacturer #2's navigation page.

Up Bolt Coefficient Attach Transducer & Get A Good Signal Record Tensions, M2 Add Data Month Later...

 

 

 

 

FAST-DAQ
Let us know how we can help you.

Telephone
(800) 732-7832
Postal address
1022 Antelope Trail, Winter Springs, FL 32708, USA

Send your email to with questions or  comments about how we can help. Contact us here, or type in the email address shown above (Due to spam, we have replaced the text email address, with the image email address shown above).

Note: Privacy. We will NOT give your contact information to anyone.

 No more guessing as to which "one point" is the right point.


 

The FIRST whole echo method (patented DSP Technique).

SureBolt picture

Built into a 
Panasonic Toughbook

Weather proof keyboard.

Visitors Since 1-22-02 Hit Counter
Last Modified: September 27, 2011